Company News About What do you know about the precautions for using a pre configured luminol solution?

What do you know about the precautions for using a pre configured luminol solution?

2024-08-20
What do you know about the precautions for using a pre configured luminol solution?

The configured luminol solution is highly valued for its high sensitivity detection ability for trace amounts of blood in forensic medicine and crime scene investigations. However, its use is accompanied by a series of strict operating procedures and precautions aimed at ensuring the accuracy of detection and the safety of operators. This article will provide a detailed introduction to the key points that should be paid attention to when using a pre configured luminol solution, from the preservation and handling of the solution to the detailed control in practical applications, aiming to provide a comprehensive operating guide.


Preservation and Management of Solutions


1. Light shielded storage: Luminol is sensitive to light, and prolonged exposure to light can accelerate its decomposition and reduce detection sensitivity. Therefore, the prepared solution needs to be stored in a dark container and placed in a dark, low-temperature environment, such as a refrigerator compartment, to extend its shelf life.


2. Avoid high temperatures: In addition to avoiding light, it is also necessary to prevent high temperature environments, as high temperatures can also enhance the degradation of luminol and affect its chemical stability. The ideal storage temperature is generally between 2-8 ° C.


3. Sealed storage: In order to reduce contact with air, the container should be well sealed to avoid the oxidation of luminol solution by oxygen. In some cases, replacing the air inside the container with inert gases such as nitrogen can further enhance the protective effect.

 

Operating procedures


1. Personal protection: When handling luminol solution, it is necessary to wear appropriate personal protective equipment, including but not limited to lab coats, disposable gloves, goggles, and masks. Although luminol is not highly toxic, it is irritating to the skin and eyes and may produce harmful vapors.


2. Pre use inspection: Before each use, the solution should be checked for precipitation or discoloration, which may be a sign of solution failure or contamination. Expired or deteriorated solutions should be immediately discarded and cannot be used.


Control during application process


1. Environmental control for on-site applications: When conducting on-site inspections, it is necessary to ensure that the ambient light is as dim as possible, as even weak light can affect the luminescence effect of luminol. At the same time, it is important to avoid air drying and interference from other pollutants.


2. Solution ratio and mixing: Before use, the luminol solution should be mixed with hydrogen peroxide (H2O2) and possible catalysts (such as iron ion solution) in a specific ratio. The mixing ratio must strictly follow the experimental plan, as excessive or insufficient mixing can affect the luminescence intensity and detection accuracy.


3. Reaction time and observation: The luminescence phenomenon of the reaction between luminol and hemoglobin usually reaches its peak within a few seconds to minutes. Operators should be patient and wait to avoid premature evaluation of the results. At the same time, using professional equipment such as scotches or cameras can improve the sensitivity of observation and the accuracy of recording.


Identification and elimination of interference factors


1. Environmental disruptors: Some cleaning agents, bleaching agents, and other substances may react with luminol, producing false positive results. Therefore, understanding the on-site background and pre-processing steps are crucial, and small-scale pre tests can be conducted if necessary.


2. Biological interference: Animal blood, urine, etc. may also cause a luminol reaction, and the test results need to be further verified in conjunction with other forensic testing methods.

 

Subsequent processing and reporting


1. Sample collection: Upon discovering suspected bloodstains, immediate labeling and appropriate measures should be taken to collect samples for further forensic identification such as DNA analysis.


2. Record and report: Detailed record of the testing process, including the batch number of luminol solution used, mixing ratio, reaction conditions, observed phenomena, etc., providing accurate basis for subsequent analysis and court testimony.


The correct use of luminol solution is a key skill in forensic practice, which not only requires the operator to possess professional chemical knowledge, but also requires a rigorous experimental attitude and meticulous operational skills. By strictly adhering to the above precautions, the accuracy and reliability of luminol detection can be improved, providing strong support for case investigation. With the advancement of technology and continuous exploration of new optimization strategies and techniques, the application boundaries of luminol in crime scene investigation will be further expanded. As a manufacturer of luminescent reagents, Desheng has a complete range of luminol types, high sensitivity, and professional personnel to track and guide, helping to solve technical problems. If you have any relevant intentions, please click on the website to inquire about details!