logo
Wuhan Desheng Biochemical Technology Co., Ltd
Über uns

Wuhan Desheng Biochemical Technology Co., Ltd

UnternehmensvorstellungWuhan Desheng Biochemical Technology Co., Ltd. wurde 2005 gegründet und hat seinen Sitz in Wuhan, China. Das Unternehmen ist spezialisiert auf Forschung und Entwicklung, Produktion und Vertrieb von Blutentnahmeröhrchen-Zusatzstoffen und homologen chemischen Reagenzien.Wir beschäftigen uns hauptsächlich mit Reagenzien zur Vorbehandlung von Blutproben, einschließlich Antikoagulanzien-Serien: Lithiumheparin, Natriumheparin, EDTA K2/K3, Blutgerinnsel-Serien: Pulver und Fl...
Weitere Informationen
China Wuhan Desheng Biochemical Technology Co., Ltd

2005

Jahr der Gründung

10000000 +

Jahresumsatz

>100 +

Mitarbeiter

Nachrichten
Go to Shanghai for an appointment! Hubei Xindesheng invites you to gather at analytica China 2026
2026-10-29
From November 16th to 18th, 2026, the Munich Analytical Biochemistry China Exhibition (analytica China 2026) will be held at the Shanghai New International Expo Center. As an important exhibition in the fields of analysis, biochemistry, and laboratory technology in Asia, analytica China gathers global instrument manufacturers, reagent suppliers, research institutions, and laboratory end-users. It is an important window for observing technological trends and connecting upstream and downstream resources. For biochemical raw material enterprises, this exhibition is not only a place to showcase products, but also an opportunity for face-to-face communication with downstream users such as reagent development, inspection and testing, scientific research experiments, etc. Hubei Xindesheng Material Technology Co., Ltd. has confirmed its participation in the exhibition, with booth number N4-4113. The company will showcase its core product matrix, including biological buffering agents, blood collection tube additives, chromogenic substrates, and enzyme preparations, targeting application scenarios such as in vitro diagnostics, biomedicine, and laboratory research, demonstrating the supply capability and technological accumulation of domestic biochemical raw materials. Exhibition Preview: Biochemical Raw Material Matrix Covering Multiple Scenarios At this exhibition, Xindesheng will focus on showcasing several types of products closely related to laboratory analysis and biochemical research. In terms of biological buffering agents, more than 50 products including TRIS, HEPES, MOPS, CAPS, TAPS, etc. form a matrix with a stable purity of over 99%. The indicators can be customized according to customer application scenarios. Buffer agents may seem basic, but they directly affect the pH stability of experimental systems such as electrophoresis, chromatography, and cell culture. The pKa range, temperature dependence, and metal ion complexation tendency of different buffering agents vary. Whether the selection is matched often affects the experimental reproducibility and inter batch consistency of the reagent kit. The blood collection tube additive series is also a key focus of the exhibition. More than 20 products including serum separation gel, heparin lithium, heparin sodium, EDTA dipotassium/tripotassium/disodium, coagulant, coagulant powder, etc. support one-stop procurement to serve the formulation and process needs of blood collection tube production enterprises. This type of product requires high batch stability and coating performance, and the on-site technical team can communicate with customers based on their actual production processes. In terms of chromogenic substrates, Trinder's reagents such as TOOS, MAOS, DAOS, etc. are compared with similar foreign products, and some indicators have characteristics in low background interference and color stability. They have been applied in various types of in vitro diagnostic kits. For reagent manufacturers who are optimizing biochemical testing projects such as uric acid, kidney function, and blood glucose, the control of impurities in chromogenic substrates and inter batch differences are topics worth discussing on site. In addition, the enzyme preparation project team established by the company since 2024 will also showcase its related products, demonstrating its extension in the upstream raw material direction of diagnostic reagents. Company Strength: Two Bases and Capacity Support Hubei Xindesheng Material Technology Co., Ltd. was registered and established in 2017, formerly known as Wuhan Desheng Biochemical Technology Co., Ltd. established in 2005. The company is headquartered in Guanggu United Science and Technology City, Gedian Development Zone, Ezhou City, Hubei Province. It has two research and development production bases, Gedian (54 acres) and Huanggang (70 acres), with an annual production capacity of 5000 tons for all categories. With the commissioning of the new Huanggang factory, the production capacity of biological buffering agents, carbomers and other products has been further improved, providing more stable supply guarantees for the fields of biomedicine and daily chemical products. These production capacity layouts are the practical basis that customers pay more attention to when evaluating raw material suppliers. On site communication: come with questions, go with ideas During the exhibition, the sales and technical R&D team of Xindesheng will be stationed throughout the entire process. Whether it's confirming product parameters, matching application scenarios, or selecting raw materials for reagent kit development and process scaling, face-to-face communication can be conducted at the booth. For customers who are interested in cooperation, it is recommended to sort out the demand list in advance, such as target testing items, pain points in existing formulas, tolerance range for batch differences, etc. The on-site communication will be more targeted. Analytica China is not only a platform for showcasing products, but also an opportunity for industry colleagues to exchange technology and explore trends. Hubei Xindesheng cordially invites all new and old partners to visit booth N4-4113 to discuss products, applications, and cooperation. We look forward to meeting you in Shanghai, living up to our expectations, and sharing a beautiful journey together!
Weitere Informationen
Latest company news about Go to Shanghai for an appointment! Hubei Xindesheng invites you to gather at analytica China 2026
PH adjustment timing and temperature compensation: common judgment bias in Bicine working solution preparation
2026-10-30
When preparing Bicine buffer, pH adjustment and temperature compensation are two seemingly basic but prone to judgment bias. Many experimenters are accustomed to processing Bicine according to the conventional buffer preparation process, but the temperature dissociation characteristics and pH response behavior of this reagent have their own characteristics. Starting from operational details, this article analyzes common misconceptions in pH adjustment timing and temperature compensation, and provides corresponding correction ideas. 1.The concentration deviation problem of adjusting pH in advance when dissolution is incomplete When preparing Bicine working solution, some operators start adding sodium hydroxide or hydrochloric acid dropwise to adjust the pH before the solid powder is completely dissolved. As the undissolved Bicine particles are still in a solid phase and have not yet participated in proton equilibrium in the solution, the measured pH value only reflects the dissociation state of the dissolved part. As the stirring progresses, the remaining powder gradually dissolves, and the newly added solute molecules introduce additional hydrogen ion release or binding, causing the already adjusted pH to drift. The experimenters added acid and alkali again to correct this drift, and after repeated operations, the volume of the solution significantly increased, resulting in the actual concentration of Bicine being lower than the target value. The correct sequence should be to wait until the powder is completely dissolved and the solution is in a uniform and transparent state before starting pH adjustment, and to maintain continuous stirring during the adjustment process to ensure that the reading reflects the equilibrium state of the entire solute. 2.PH deviation caused by inconsistent temperature adjustment and usage temperature The dissociation constant of Bicine changes with temperature, which means that the pH value of its buffer solution varies at different temperatures. If the target pH is lowered at room temperature (about 25 degrees Celsius) and then used at 4 degrees Celsius or 37 degrees Celsius, the actual pH of the solution will deviate from the set value. The direction and magnitude of this deviation depend on the temperature range. For Bicine, a decrease in temperature usually causes a slight increase in pH value, while an increase in temperature causes a slight decrease in pH. If the experimenters are not aware of this change, they may mistakenly believe that the stability of the buffer solution is poor or that the pH meter is malfunctioning. The method to avoid this problem is to complete pH adjustment under the same temperature conditions as the subsequent experiments. If the experimental design involves multiple temperature nodes, the pH shift of Bicine buffer at different temperatures can be measured in advance, and the corresponding values at the actual usage temperature can be indicated in the record. 3.Application boundary of pH electrode temperature compensation function Most modern pH meters have automatic temperature compensation function, which mainly corrects the change in electrode slope with temperature, rather than correcting the pH temperature coefficient of the buffer solution itself. Some experimenters equate temperature compensation with "automatic correction of buffer pH", but this understanding is not accurate. Temperature compensation only allows the electrode to provide more accurate measurement values at different temperatures, and cannot change the actual pH drift of Bicine solution caused by temperature changes. Therefore, even if the pH meter displays a certain value, it only represents the true value measured at the current temperature and does not represent that the solution still maintains the same pH at other temperatures. The correct approach is to set the working temperature when adjusting the pH and indicate the measured temperature when recording to avoid directly comparing readings at different temperatures. 4.Missing backtesting after buffer preheating or pre cooling After high-temperature sterilization, water bath preheating, or ice bath pre cooling, the pH value of Bicine working solution will temporarily change due to temperature changes. When the solution returns to room temperature, the pH will return to the original set value. But if the temperature changes dramatically or lasts for a long time, irreversible changes such as solute precipitation, carbon dioxide dissolution, or water evaporation may occur in the solution, resulting in a deviation between the pH value after recovering to room temperature and the original value. Many operators measure and adjust the pH before processing, and use it directly after temperature treatment without conducting a retest, which may introduce the deviated pH into the reaction system. It is recommended to take a small amount of solution and reheat it to the adjusted temperature after temperature treatment and before contacting the sample, and retest the pH to confirm that the changes are within an acceptable range before proceeding with subsequent operations. PH adjustment and temperature compensation themselves are not complicated, but each step in the operation carries the accuracy of the final state of the buffer solution. By grasping these two details, the experimenters can enable the Bicine working fluid to play its due buffering role in its set environment, and provide a basic guarantee for the comparability of experimental data. As a professional manufacturer of BICINE, Desheng has established a comprehensive quality control system and strictly controls every production process to ensure that the product quality meets the requirements. And we have a professional sales and technical team that can quickly respond to customer needs and issues, providing timely and professional services to customers. If you have any needs, please feel free to contact us at any time!  
Weitere Informationen
Latest company news about PH adjustment timing and temperature compensation: common judgment bias in Bicine working solution preparation
Key points for the use of MOPS in laboratory standardization operations
2026-10-26
In the daily operation of the laboratory, the preparation and use of buffering agents may seem basic, but they directly affect the stability of experimental results. MOPS, as a commonly used biological buffer, is called 3-methylmorpholinopropane sulfonic acid in Chinese, abbreviated as MOPS Buffer, with a CAS number of 1132-61-2. This product is a white crystalline powder with a purity of not less than 99% and good water solubility. It is suitable for protein purification, electrophoresis analysis, embryo culture, and plant hydroponics. From the perspective of standardized operation, the following outlines the aspects worth paying attention to when using this product. Product Identification and Basic Cognition When receiving MOPS raw materials, the label information should be checked first, including Chinese name, English name, abbreviation, CAS number, molecular formula C7H15NO4S, and molecular weight 209.26. These pieces of information form the basis for subsequent recording and tracing. The appearance of the product should be white powder. If there is a significant change in color, it needs to be evaluated before use. Its density is 1.298, melting point is between 277 and 282 degrees Celsius, refractive index is 1.512, and flash point is 116 degrees Celsius. These parameters help to determine whether the product is in a normal state and provide reference for weighing and dissolution operations during preparation. Preparation of environment and equipment before preparation The storage conditions for MOPS include two methods: room temperature, avoiding light and moisture, and cold storage. If the laboratory humidity is high or the usage is frequent, cold storage can be preferred for storage. Before preparation, the necessary equipment should be cleaned thoroughly to avoid residual acids, alkalis, or organic solvents affecting the performance of the solution. It is recommended to use a dry container for weighing, as the product has a PSA of 75.22000 and a large polar surface area. The powder has a certain affinity for moisture, and quick weighing and timely sealing can reduce moisture absorption. The preparation water should be clean, and the container should be free of particles to ensure the appearance of the subsequent solution. Dissolution and solution appearance inspection MOPS has good water solubility and can be dissolved by stirring at room temperature, usually without heating. If the solution becomes clear and transparent after dissolution, it indicates that the dissolution process is normal. If there is turbidity or suspended matter, the water quality, container cleanliness, or whether the raw materials are damp should be checked. Its LOGP is 0.61520, indicating strong hydrophilicity and uniform distribution in the aqueous phase. After preparation, observe whether the solution has any abnormal color. Normal MOPS solution should not have obvious chromaticity. PH adjustment and temperature recording The pKa value of MOPS remains stable between 6 and 8, and is largely unaffected by ion concentration, composition, and temperature. When adjusting pH, an appropriate acid or alkali solution should be used, slowly added and continuously stirred to avoid local over acidification or over alkalinity. Due to the subtle influence of temperature on pH readings, it is recommended to record the solution temperature during adjustment and conduct final confirmation at the actual experimental temperature. This product has no obvious absorption characteristics at actual ultraviolet wavelengths, so the adjusted solution can be directly used for photometric determination without worrying about background interference. Sterilization and storage management When used for embryo culture or cell related experiments, MOPS working solution needs to undergo sterilization treatment. This product has stable chemical properties and is non-toxic to biological cells in experiments, ensuring safety during use. The sterilization method should be filtration rather than high-temperature and high-pressure sterilization. If the prepared working fluid cannot be used in a timely manner, short-term refrigeration or packaged freezing should be selected based on whether it contains nutritional components. The original packaging powder should be sealed and stored to avoid moisture absorption and clumping. If the powder clumps but the color remains unchanged, it can be used after drying; If the color turns yellow, it is not recommended to continue using it. Hubei Xindesheng Material Technology Co., Ltd. is a supplier of MOPS buffer raw materials, with accurate buffering range and equipped with usage guidelines. It provides detailed information on the amount of MOPS buffer raw materials added, preparation methods, and compatibility considerations with other reagents in different experimental scenarios. Researchers and business producers can quickly get started and fully utilize the performance of MOPS buffer, greatly improving experimental and production efficiency. If you have any purchasing needs, please feel free to contact us!
Weitere Informationen
Latest company news about Key points for the use of MOPS in laboratory standardization operations
HEPES preparation should avoid these misconceptions in order to ensure accurate concentration
2026-10-29
The accuracy of HEPES buffer concentration directly affects the reliability of experimental results. However, in practical operation, deviations may be introduced in multiple stages from weighing to volume determination. Some deviations are easily detected, while others accumulate covertly. Understanding the causes and avoidance methods of these common misconceptions can help experimenters obtain buffer solutions with reliable concentrations. Common deviations in the weighing process HEPES powder has hygroscopicity, which is one of the main sources of weighing errors. If the product is exposed to a humid environment for a long time after opening, the actual proportion of effective ingredients in the powder will decrease after absorbing moisture, which will result in a lower concentration when weighed according to theoretical quality. It is recommended to seal and store after opening, and use desiccants to measure quickly and reduce the contact time between powder and air. Attention should also be paid to the selection of scales. Analytical scales should be calibrated regularly, and the peeling operation of weighing paper or containers cannot be omitted. If the weighing amount is small, ordinary scales with insufficient accuracy should be avoided, otherwise the relative error may exceed the acceptable range. Operation details in dissolution and constant volume The dissolution process of HEPES requires sufficient stirring, but too fast stirring speed may introduce bubbles, affecting the accuracy of subsequent volumetric readings. Some experimenters are accustomed to dissolving in a beaker and transferring it to a volumetric flask. If the washing is not sufficient during the transfer process, solute loss can lead to low concentration. The correct approach is to rinse the inner wall of the beaker multiple times with a small amount of solvent and transfer the washing solution into a volumetric flask. When setting the volume, it is necessary to wait for the solution temperature to return to room temperature before proceeding, as differences in ambient temperature may affect the liquid volume. Before using a volumetric flask, it should be checked for cleanliness and whether the stopper matches to avoid leakage or deviation in the scale reading. The impact of pH adjustment on actual concentration The pH adjustment process of HEPES solution introduces additional ions into the system. When using sodium hydroxide solution to adjust pH, sodium ions enter the solution; When using hydrochloric acid, chloride ions are introduced. The addition of these ions does not change the molar concentration of HEPES, but increases the total ion strength of the solution. If the experiment is sensitive to ion strength, it is necessary to recheck the conductivity or adjust the amount of other salts added appropriately after adjusting the pH. In addition, pH adjustment should be carried out after HEPES is completely dissolved and the temperature is stable. If acid and alkali are added in advance during the dissolution process, it may cause uneven local concentration and affect the judgment of the adjustment endpoint. The influence of storage conditions on concentration stability The prepared HEPES solution may concentrate due to water evaporation or deteriorate due to microbial growth during storage. When an open container is placed, slow solvent evaporation can increase solute concentration, especially on a well ventilated experimental platform. It is recommended to use a sealed container and store it in a cool place. If the solution needs to be stored for a long time, it can be packaged and refrigerated to reduce concentration changes caused by repeated opening of the lid. Solutions containing HEPES should not be stored at high temperatures, as temperature fluctuations may accelerate chemical degradation or promote microbial growth. Observe the solution for turbidity, precipitation, or color changes before each use to preliminarily determine whether it can still be used. Overall, the accuracy of HEPES buffer concentration depends on standardized operations in multiple stages such as weighing, dissolution, volume control, adjustment, and storage. Moisture absorption, transfer loss, and evaporation concentration are common sources of deviation, which can be controlled through sealed storage, thorough washing, and regular validation. For routine laboratories that use AR to analyze pure grade products, establishing concise preparation records and validation habits can help ensure the quality of buffer solutions while keeping costs under control. As a HEPES buffer manufacturer, Desheng strictly monitors product quality and sets up a quality department to inspect batches of products. Only after the packaging and quality meet the standards can they be sold from the factory. Therefore, Desheng has received unanimous praise from customers. If you have any relevant intentions, please click on the website to inquire about details and purchase!
Weitere Informationen
Latest company news about HEPES preparation should avoid these misconceptions in order to ensure accurate concentration
Was haben sie gesagt?
tony
tony
Als Verteiler des Krankenhausmittels, ist Ihre Blut-Sammlungs-Rohr-Zusätze sehr Klage für meinen Bedarf, ich denken, dass wir haben, ein gutes Geschäft mit einander herzustellen, danke!
Als Verteiler des Krankenhausmittels, ist Ihre Blut-Sammlungs-Rohr-Zusätze sehr Klage für meinen Bedarf, ich denken, dass wir haben, ein gutes Geschäft mit einander herzustellen, danke!
Wilhelm
Wilhelm
Wir haben die Probebestellung erhalten und den Test bestanden. Vielen Dank für all Ihre Bemühungen. Sie sind ein zuverlässiger Partner! Wir werden in Zukunft mit Ihnen zusammenarbeiten.
Wir haben die Probebestellung erhalten und den Test bestanden. Vielen Dank für all Ihre Bemühungen. Sie sind ein zuverlässiger Partner! Wir werden in Zukunft mit Ihnen zusammenarbeiten.
Marinel
Marinel
Der biologische Puffer, der von der Firma Desheng hergestellt wird, hat eine hohe Reinheit, eine gute Wasserlöslichkeit und ein weißes Pulver.uns hilft, den biologischen Puffer richtig und effizient zu nutzenEs war eine sehr gute Erfahrung, ich freue mich auf die nächste Zusammenarbeit!
Der biologische Puffer, der von der Firma Desheng hergestellt wird, hat eine hohe Reinheit, eine gute Wasserlöslichkeit und ein weißes Pulver.uns hilft, den biologischen Puffer richtig und effizient zu nutzenEs war eine sehr gute Erfahrung, ich freue mich auf die nächste Zusammenarbeit!
Senden Sie Ihre Anfrage
Bitte senden Sie uns Ihre Anfrage und wir werden Ihnen so schnell wie möglich antworten.
Senden