제품 세부 정보
원래 장소: 후베이
브랜드 이름: desheng
인증: ISO9001
모델 번호: CAS 150-25-4
지불 및 배송 조건
최소 주문 수량: 20kg
가격: Detailed discussion
포장 세부 사항: 20kg / box
배달 시간: 5일
지불 조건: L/C, D/P, T/T, 웨스턴 유니온
공급 능력: 5T/주
모습: |
백색분말 |
모델: |
비시네 |
제조업체: |
Desheng |
포장: |
500g / box |
모습: |
백색분말 |
모델: |
비시네 |
제조업체: |
Desheng |
포장: |
500g / box |
When preparing buffer solutions, water quality is often considered a secondary variable, but this judgment may lead to cumulative errors in the Bicine system. As a zwitterionic buffer, Bicine's effective buffering range, dissolution behavior, and interaction with solutes are closely related to the purity of the solvent water. Starting from the actual impact of water quality differences, this article provides actionable suggestions for water quality management and investigation for experimental personnel.
|
Chemical Name |
N. N-dihydroxyethylglycine |
Product Name |
BICINE buffer |
|
Product Appearance |
White crystalline powder |
CAS Number |
150-25-4 |
|
Molecular Formula |
C6H13NO4 |
Molecular Weight |
163.17 |
|
Storage Conditions |
Room temperature, away from light and moisture |
Purity |
More than 99% |
|
Product Use |
Used for enzyme reaction buffer, etc |
Product Packaging |
500g/bottle |
|
Product Advantages |
Good water solubility and stable chemical properties |
Manufacturer |
Hubei Xindesheng |
1, The interference mechanism of trace impurities in water on Bicine buffer capacity
The buffering capacity of Bicine depends on the balance between protonation and deprotonation of its molecules in solution. When the preparation water contains a certain amount of carbonate, silicate, or metal ions, these impurities will participate in the ion balance in the solution. Carbonate ions introduce additional acidity regulation requirements under weakly alkaline conditions, resulting in actual pH deviating from the theoretical calculated value. If experimenters use water that has not been thoroughly purified, they may need to consume more sodium hydroxide or hydrochloric acid to correct the pH, and the additional titration process introduces new ion strength variables. This interference will be amplified in low concentration Bicine working solution because the concentration of the buffer substance itself is low, the proportion of impurities is relatively increased, and the buffer capacity is further weakened.
![]()
Bicine powder
2, Concealed consumption of metal ions in water through complexation with Bicine
The tertiary amine and hydroxyl groups in the molecular structure of Bicine have the ability to chelate metal ions, which can reduce metal interference in specific experiments. However, this also means that trace metals (such as iron, copper, or zinc) in the preparation water will undergo binding reactions with Bicine. This type of complexation does not consume the main body of Bicine, but changes the ratio of free Bicine to metal bound Bicine in the solution, resulting in the actual number of molecules involved in buffering being lower than the calculated weight. When using deionized water or distilled water with poor purity, the concentration of metal ions may reach the micromolar level. For millimolar Bicine working fluids, this consumption ratio has become a significant systematic error that cannot be ignored. More noteworthy is that the complex products may have different charge states from free Bicine, resulting in additional signal shifts in electrochemical detection or ion exchange chromatography.
3, The superposition effect of organic pollutants on the background of Bicine UV detection
The low UV absorption characteristic of Bicine is an important advantage for its suitability for chromatographic and spectroscopic detection. However, organic residues in the preparation water, such as disinfection by-products, pipeline precipitates, or microbial metabolites, may generate background absorption near Bicine's characteristic absorption wavelength. This interference is particularly evident in the gradient elution process, as there are differences in the retention behavior of organic matter and Bicine on the chromatographic column, resulting in irregular baseline drift. For experiments that require high-sensitivity detection, even if the concentration of organic matter in water is within the allowable range of conventional pure water indicators, the background signal may still accumulate to the level of interfering with quantitative analysis after concentration effect of Bicine buffer or long-term cyclic use.
4, The practical correlation between water quality resistivity and pH stability of Bicine working fluid
Electrical resistivity is a comprehensive indicator for measuring the total amount of ions in water, but its value cannot fully represent whether the water quality is suitable for Bicine preparation. If high resistivity ultrapure water comes into contact with air during storage or retrieval, it will absorb carbon dioxide to form carbonic acid, which will increase the measured conductivity. The initial pH of the buffer solution obtained by preparing Bicine with water that has absorbed carbon dioxide will be lower than expected, and additional alkaline solution needs to be added dropwise for adjustment. This additional operation changes the original ratio of buffer pairs, reducing the working fluid's tolerance to external acidity and alkalinity. If the test personnel take water at different time points to prepare the same batch of buffer solution required for the experiment, it may cause batch deviation in pH due to different carbon dioxide contents in the water, which affects the comparability between experiments.
5, Quick investigation methods and daily management suggestions for water quality impact
When there is abnormal pH adjustment, elevated blank baseline, or fluctuation in the background signal of the reaction system in Bicine buffer, auxiliary verification of the prepared water can be performed first. Prepare Bicine solution with the same concentration using ultrapure water and conventional purified water of the same volume, and measure the pH value and UV scan spectrum in parallel. If the difference between the two exceeds the experimental tolerance range, the water source needs to be improved. In daily operation, it is recommended to use it promptly after taking water to avoid long-term storage; Water containers should be regularly cleaned and dedicated to prevent detergent residues from introducing pollutants. For the ultra pure water machine system, the pre-treatment column and UV lamp should be replaced regularly according to maintenance standards to ensure that the total organic carbon content in the produced water is maintained at a low level. Adding the electrical resistivity of water and the date of water intake to the test records facilitates the correlation between abnormal phenomena and changes in water quality in the future.
The choice of water is not the most concerning topic in Bicine's use, but it is the key foundation that determines whether the buffering system can stably support the experiment. Controlling water quality from the source is not only a respect for the performance of Bicine products, but also a practical action responsible for the reproducibility of experimental data.
![]()
Product packaging
As a professional manufacturer of BICINE, Desheng has established a comprehensive quality control system and strictly controls every production process to ensure that the product quality meets the requirements. And we have a professional sales and technical team that can quickly respond to customer needs and issues, providing timely and professional services to customers. If you have any needs, please feel free to contact us at any time!