logo
Wuhan Desheng Biochemical Technology Co., Ltd
Wuhan Desheng Biochemical Technology Co., Ltd
products
Home /

products

What are the process methods for treating blood collection tubes with silicification agents

Product Details

Place of Origin: EZHOU,CHINA

Brand Name: DESHENG

Certification: ISO9001:2008

Model Number: Silicon Oil

Payment & Shipping Terms

Minimum Order Quantity: 1L

Price: Negotiable

Packaging Details: Plastic Bottle and Carton Box

Delivery Time: 1~3 DAYS AFTER RECEIVING PAYMENT

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,paypal

Supply Ability: 1000L/month

Get Best Price
Contact Now
Specifications
Highlight:

Silicone Oil

,

Blood Collection Tube Additives

Color:
Colorless And Transparent Liquild
Grade:
AR Degree
Product Name:
Silicone Oil
Appearance:
Colorless
Viscosity:
(at 25 ° C) 425mm2 · S -1
Relative Density:
(at 25 ° C) 1.070
Color:
Colorless And Transparent Liquild
Grade:
AR Degree
Product Name:
Silicone Oil
Appearance:
Colorless
Viscosity:
(at 25 ° C) 425mm2 · S -1
Relative Density:
(at 25 ° C) 1.070
Description
What are the process methods for treating blood collection tubes with silicification agents

Silicified blood collection tubes are an important tool commonly used in modern medical laboratories and clinical diagnosis. Their main function is to prevent blood samples from adhering to the test tube wall during collection and processing through silicon treatment of the inner wall, thereby improving the accuracy of blood collection and detection. Siliconization agent, as a chemical reagent used to treat the inner wall of blood collection vessels, is usually composed of high molecular weight organic silicon materials. These chemicals form a dense coating on the inner wall of the blood collection tube through chemical reactions, giving the tube wall excellent hydrophobicity and anti adhesion properties.


Product Name Water soluble silicide agent Efficient silicification agent (oil silicon)
Product appearance Colorless, odorless, transparent to cloudy liquid Colorless to light yellow transparent liquid
Packaging specifications 1L/bottle, 5L/barrel 1L/bottle, 5L/barrel
Validity period 30 months Five years (based on production date)
Purpose Make the inner wall of the blood collection vessel transparent and smooth, preventing phenomena such as wall hanging and hemolysis in blood samples
Origin Ezhou City, Hubei Province


The role of silicification agents in blood collection tubes


1. Preventing blood adhesion: After silicification treatment, the inner wall of the blood collection tube is smooth, which can prevent blood cells and proteins from adhering to the tube wall.


2. Improve sample quality: reduce the retention and deterioration of blood samples on the tube wall, ensuring the accuracy of test results.


3. Reduce hemolysis: Silicification treatment can reduce hemolysis during blood collection and protect the integrity of blood cells.


What are the process methods for treating blood collection tubes with silicification agents 0



The treatment process method of silicification agent blood collection tube


Solution method:


1. Process principle


Solution method is one of the commonly used silicification treatment methods. The principle is to dissolve the silicification agent in an organic solvent, and then immerse the blood collection tube into the solution, so that the silicification agent forms a uniform coating on the inner wall of the blood collection tube.


2. Process steps


(1) Preparation of silicification solution: Dissolve the silicification agent in a suitable organic solvent to prepare the silicification solution.


(2) Immersion treatment: Immerse the clean blood collection tube into a silicification solution and maintain it for a period of time to ensure that the solution fully covers the inner wall of the blood collection tube.


(3) Drying and curing: Remove the blood collection tube, drain excess solution, and then heat and cure in a drying oven to allow the silicification agent to react chemically with the glass tube wall, forming a stable coating.


Spraying method:


1. Process principle


Spray coating is a method of forming a coating by spraying silicification reagents onto the inner wall of a blood collection tube.


2. Process steps


(1) Preparation of spray solution: Dissolve the silicification reagent in organic solvents to prepare the spray solution.


(2) Spray treatment: Spray the spray solution evenly onto the inner wall of the blood collection tube.


(3) Drying and curing: Place the sprayed blood collection tube in a drying oven to heat and cure, forming a stable coating.


Dip coating method:


1. Process principle


The dip coating method is to immerse the blood collection tube into a silicified solution, and during pulling, by controlling the immersion speed and solution concentration, the solution is uniformly coated on the inner wall of the blood collection tube to form a coating.


2. Process steps


(1) Preparation of coating solution: Dissolve the silicification reagent in an appropriate solvent to prepare the coating solution.


(2) Dip coating treatment: Dip the blood collection tube into the dip coating solution, hold it for a period of time, and then slowly pull it to evenly coat the tube wall with the solution.


(3) Drying and curing: Cure the coated blood collection tube in a drying oven.,


What are the process methods for treating blood collection tubes with silicification agents 1

Product packaging


Quality control of silicification treatment


1. Coating thickness: The thickness of the siliconized coating is an important factor affecting the performance of blood collection tubes. Thick coating can affect transparency and observation effect, while thin coating can easily lead to coating peeling. The coating thickness should be strictly controlled within the specified range through equipment such as coating thickness gauges.


2. Coating uniformity: The uniformity of the coating directly affects the anti adhesion performance of the blood collection tube. Inspect the surface of the coating through various inspection methods to ensure uniformity and absence of defects.


3. Coating adhesion: The adhesion of the coating is the key to ensuring the long-term effectiveness of siliconized blood collection tubes. By using methods such as scratch testing and peel testing, the adhesion of the coating is tested to ensure that it is not affected during use.


There are various methods for treating blood collection tubes with silicification agents, each with its own advantages and applicable scope. Choosing the appropriate process method can not only improve the quality and performance of blood collection tubes, but also meet different experimental and clinical needs. As a research and development manufacturer of silicification agents and other blood collection tube additives, Desheng can supply advantageous silicification agent products with excellent silicification effects, resulting in smooth blood collection without hanging on the wall. Moreover, the manufacturer's selling price is cheap and the after-sales service is complete. If you have any relevant intentions, please feel free to click on the website to inquire about details and purchase at any time!

Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send