logo
Wuhan Desheng Biochemical Technology Co., Ltd
Wuhan Desheng Biochemical Technology Co., Ltd
products
Home /

products

Customized specific gravity of serum separation gel for PRP tube

Product Details

Place of Origin: EZHOU,CHINA

Brand Name: DESHENG

Certification: ISO9001:2015

Payment & Shipping Terms

Minimum Order Quantity: 20Kg

Price: Negotiable

Packaging Details: Plastic or iron drum

Delivery Time: 1~3 DAYS AFTER RECEIVING PAYMENT

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,paypal

Supply Ability: 30000kg/month

Get Best Price
Contact Now
Specifications
Highlight:

prp gel

,

Serum separation gel

,

Blood Collection Tube Additives

Grade:
AR Grade
Specific Gravity:
1.070-1.078g/cm3
Color:
Light Yellow
Certificate:
ISO9001:2015 National Patent
Viscosity:
(13-20)*10^4 MPa.s
Fluidity:
≤3mm
Centrifuge Test:
≥5mm
Bubble:
None
Physiological Inertia:
No Influence For Blood Test
Volatility:
≤0.8
Grade:
AR Grade
Specific Gravity:
1.070-1.078g/cm3
Color:
Light Yellow
Certificate:
ISO9001:2015 National Patent
Viscosity:
(13-20)*10^4 MPa.s
Fluidity:
≤3mm
Centrifuge Test:
≥5mm
Bubble:
None
Physiological Inertia:
No Influence For Blood Test
Volatility:
≤0.8
Description
Customized specific gravity of serum separation gel for PRP tube

In the fields of modern medicine and biological research, platelet rich plasma (PRP) has applications in tissue repair, regenerative medicine, and beauty due to its abundance of various growth factors. The efficient extraction of PRP relies on high-quality blood collection tubes and their key component - serum separation gel. PRP adhesive, a resin specifically designed for PRP blood collection vessels, plays an important role in the PRP extraction process due to its unique performance advantages.


Product Name Serum separation gel
Relative gravity 1.045-1.065g/cm3
viscosity 100000 to 300000 millipascals
Volatile matter ≤1.5%
Product appearance Colorless transparent colloid with a faint odor and no impurities
Product performance Physiologically inert, insoluble in water, with excellent thixotropic and isolation properties
Manufacturer Hubei Xindesheng Material Technology Co., Ltd
Original factory site Ezhou City, Hubei Province


1, Accurate proportion customization to meet diverse needs


PRP high-performance resin separation gel and ordinary serum separation gel may not have significant differences in appearance, but their performance is fundamentally different. The specific gravity of ordinary separation adhesive is generally between 1.045-1.055g/cm3, while the specific gravity range of PRP resin separation adhesive is 1.045-1.050g/cm3. Desheng resin PRP adhesive can be customized according to the specific PRP usage requirements of customers. By precisely adjusting the specific gravity, it can achieve efficient separation during centrifugation, maximize platelet recovery, and meet different clinical and scientific research needs.


Customized specific gravity of serum separation gel for PRP tube 0

blood separation gel


2, Strict heat free standards ensure safe extraction


The absence of heat source is an important characteristic of PRP resin separation adhesive. The no heat source here refers to sterile conditions. During the production process, the environment must be strictly controlled to prevent the production of bacteria. The entire production process needs to be processed in a clean and sterile state, and the products sold must also be guaranteed to be sterile. This is because during the PRP extraction process, if the separation gel is contaminated with bacteria, bacteria will mix into the platelets during the extraction of rich platelets, which not only affects the quality and activity of platelets, but may also cause a series of serious problems.


3, Excellent radiation resistance ensures stable extraction


As an extraction reagent directly related to the human body, PRP blood collection tubes and their internal separation gels must undergo irradiation treatment to ensure their sterility and safety. However, ordinary separation adhesives may experience aging during irradiation, which can seriously affect their performance. The resin separation adhesive used in PRP tubes has excellent radiation resistance and can maintain structural and performance stability during irradiation. Even after multiple exposures or at higher irradiation doses, aging is not likely to occur. This anti irradiation performance enables the separation gel to maintain good performance even after irradiation, which is beneficial for efficient extraction of PRP. In practical applications, stable radiation resistance ensures that each batch of PRP blood collection tubes can meet the same quality standards.


4, Excellent hydrolysis resistance and maintenance of experimental results


In PRP tubes, separation gel does not exist in isolation and is often used in conjunction with other reagents. For example, to prevent blood clotting, sodium citrate solution or ACD solution may be added. PRP resin separation gel has excellent hydrolysis resistance, and no chemical reaction occurs whether in contact with water or in the same test tube with these anticoagulant solutions for a long time. This characteristic is crucial because once the separation gel reacts with other reagents, it may cause changes in the performance of the separation gel, such as changes in specific gravity, which in turn can affect the overall experimental results. For example, changes in the specific gravity of the separation gel may result in the inability to form a stable isolation layer during centrifugation, leading to incomplete separation of blood components. Therefore, the anti hydrolysis performance of PRP resin separation gel is an important guarantee for maintaining the stability and accuracy of PRP extraction experiments.


Customized specific gravity of serum separation gel for PRP tube 1

Product packaging


Hubei Xindesheng Material Technology Co., Ltd., as a manufacturer of PRP resin separation adhesive, has more than 20 years of industry experience and significant achievements in the research and production of separation adhesive. The company has established a professional R&D team and adopted advanced technology and strict quality control system to produce PRP resin separation gel with excellent performance, precise and controllable specific gravity, no heat source, excellent radiation and hydrolysis resistance. Our products are not only popular in major medical institutions and research institutes in China, but also exported overseas. At the same time, Xindesheng provides professional technical support and attentive after-sales service. If you have purchasing intentions, please feel free to click on the website to inquire about details at any time!

Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send