Product Details
Place of Origin: EZHOU, CHINA
Brand Name: DESHENG
Certification: ISO9001:2008
Model Number: CAPS
Payment & Shipping Terms
Minimum Order Quantity: 500g
Price: Negotiable
Packaging Details: Plastic bottle/Ctn Box
Delivery Time: 1-3 days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,
Supply Ability: 1000kg/Month
Name: |
CAPS |
Full Name: |
3-Cyclohexylaminopropanesulfonic Acid |
Apperance: |
White Crystal Powxer |
CAS#: |
1132-61-2 |
Molecular: |
C9H19NO3S |
Molecular Weight: |
221.32 |
Category: |
Good's Buffer |
Application: |
PH Adjustment |
Field: |
Bioscience |
Industry: |
Medical & Health |
Name: |
CAPS |
Full Name: |
3-Cyclohexylaminopropanesulfonic Acid |
Apperance: |
White Crystal Powxer |
CAS#: |
1132-61-2 |
Molecular: |
C9H19NO3S |
Molecular Weight: |
221.32 |
Category: |
Good's Buffer |
Application: |
PH Adjustment |
Field: |
Bioscience |
Industry: |
Medical & Health |
Nucleic acid research involves multiple steps such as extraction, amplification, hybridization, and electrophoresis, and different steps require different pH and ion environment requirements for the buffer system. CAPS Buffer, as a zwitterionic buffer in the alkaline range, can serve as an auxiliary buffering component in some nucleic acid operations, providing a relatively stable acid-base environment for the system. Understanding its applicable boundaries in these stages can help researchers make reasonable choices.
|
Product Name |
3- (cyclohexylamine) -1-propanesulfonic acid |
Chemical Abbreviation |
CAPS buffer |
|
CAS Number |
1135-40-6 |
Product Appearance |
White crystalline powder |
|
Molecular Weight |
221.32 |
Molecular Formula |
C9H19NO3S |
|
Density |
1.19g/cm3 |
Melting Point |
324℃ |
|
Storage Conditions |
Room temperature, away from light and moisture |
Standard Packaging |
25KG |
|
Water-soluble |
9 g/100 mL (20℃) |
Manufacturer |
Hubei New Desheng |
The auxiliary role of nucleic acid hybridization buffer
The hybridization reaction requires promoting the binding of the probe to the target sequence at a specific alkalinity. CAPS can be used to adjust the pH of hybridization solutions, and its lower nucleophilicity reduces side reactions to nucleic acid bases, helping to reduce background signals. During use, it should be noted that the actual pH of CAPS may slightly deviate at the hybridization temperature. Calibration should be performed near the working temperature to avoid affecting the hybridization rigor due to pH deviation. If the buffer contains denaturing agents such as formamide, the solubility and clarity of CAPS mixed with it need to be verified first.
![]()
CAPS white powder
CAPS white powder
Buffer considerations in nucleic acid electrophoresis
Tris boric acid or Tris acetic acid system is commonly used in conventional agarose gel electrophoresis, and CAPS is rarely used as the main buffer. In special electrophoresis that requires alkaline separation conditions, CAPS can provide stable pH, but it carries a negative charge on its own, which may affect the migration rate of nucleic acids. If attempting to use it, it is necessary to compare the consistency of the band position with the control system through pre experiments, and pay attention to whether there is any interaction between CAPS and nucleic acid dye. For routine fragment analysis, using a mature buffer system is more reliable.
Compatibility evaluation of amplification reaction system
Polymerase chain reaction is sensitive to buffer components, and the main buffer is usually Tris. CAPS should not replace the main buffer alone, as different polymerases have different preferences for zwitterionic buffers. But in some isothermal amplification or enzymatic nucleic acid modification reactions, CAPS can be used as an auxiliary component to participate in pH fine-tuning. Before use, small-scale testing of amplification efficiency and product specificity is required to confirm that CAPS does not inhibit enzyme activity or introduce non-specific bands.
Preservation and transportation of nucleic acid samples
Short fragment nucleic acids are relatively stable under weakly alkaline conditions. CAPS buffer can be used for short-term storage of some nucleic acid samples, and its lower metal chelating ability reduces the impact on trace metal ions in the sample. However, long-term storage still needs to consider nuclease degradation and microbial growth. It is recommended to cooperate with low-temperature storage and verify that CAPS does not interfere with subsequent enzyme reactions. During transportation, pH drift should be avoided after prolonged contact between the buffer solution and the sample. Sealing and temperature control are more critical than buffer selection.
Collaboration with nuclease inhibitors
Chelating agents are often added in nucleic acid operations to inhibit metal dependent nucleases. When CAPS coexists with chelating agents such as EDTA, attention should be paid to the synergistic effect of both on pH, especially when CAPS is in the alkaline range, deprotonation of EDTA will consume some buffer capacity. It is recommended to measure the final pH in the complete formula and evaluate the actual impact of chelating agent concentration on CAPS buffering performance to avoid pH drop in the later stages of the reaction due to insufficient capacity.
![]()
CAPS bottled
Summary
The application of CAPS in nucleic acid research is relatively limited, mainly focusing on the auxiliary regulation of hybridization buffering and partial enzymatic reactions. Its alkaline buffering capacity and low nucleophilicity have reference value in specific scenarios, but conventional electrophoresis and amplification are still dominated by mature systems. When using CAPS, verification should be based on actual nucleic acid yield, hybridization signal, and detection background, and selection should not be made solely based on pH range.
As a supplier of CAPS buffering agents, Hubei Xindesheng ensures that each batch of CAPS buffering agents has stable performance and a purity of over 99% through its processes and strict quality control system. The company has a professional R&D team that constantly explores and optimizes production processes, improves product quality, and meets increasingly diverse market demands. At the same time, Xindesheng also provides attentive customer service, offering professional technical consultation and solutions to customers. If you are interested, please feel free to click on the website for consultation at any time!